Load-Current-Dependent Adaptive Frequency Modulation for a Digitally PI-Controlled Synchronous Buck Converter
Keywords:
Adaptive frequency modulation, buck converter, digital PI control, synchronous rectification, efficiency, output voltage rippleAbstract
In this study, the efficiency performance and ripple behavior of a 24 V/12 V synchronous rectified buck converter were investigated under load-current-dependent adaptive frequency modulation (AFM). The converter was regulated using a digital PI controller, and the switching frequency was selected in discrete steps according to the filtered average inductor current. In the simulation study, values of 40 kHz, 60 kHz, 100 kHz, and 200 kHz were assigned to load currents of 1 A, 2 A, 5 A, and 10 A, respectively. The converter model was implemented in PSIM, and the output voltage , inductor current , input power , output power , and efficiency values were evaluated under steady-state operating conditions. The results showed that increasing with load current reduced both the inductor current ripple and the output voltage ripple . The decreased from approximately 2.20 A at 1 A load to approximately 0.46 A at 10 A load. Over the same load range, decreased from approximately 55 mV to 8.9 mV. The efficiency analysis based on average power values showed that the converter operated with an efficiency between approximately 98.23% and 99.42% over the 1–10 A load current range. These results indicate that AFM is an effective approach for limiting switching-related losses at light load and reducing current and voltage ripple at high load in synchronous rectified buck converters.