Fault Analysis and Diagnosis in a Three-Level NPC Voltage Inverter
Abstract views: 19 / PDF downloads: 26
Keywords:
Three-Phase Inverter With NPC Structure, PWM, MAS, DiagnosticsAbstract
This article discusses an external, qualitative method for diagnosing faults in static converters
(DC/AC) based on the analysis of current vector trajectory signatures in the stationary reference frame.
Downloads
References
Peuget, Raphael; Courtine, Stéphane; Rognon, Jean- Pierre: FaultDetection and Isolation on a PWM Inverter by Knowledge-Based Model; IEEE Transactions on Industry Applications, Vol. 34, No. 6, 1998, pp. 1318 – 1325.
Khaled chaibanou "modeling and diagnostics of the asynchronous machine using fuzzy logic techniques fuzzy logic techniques" magister thesis in electrical engineering.univ-batna 2006.
Friedrich W. Fuchs: Some Diagnosis Methods for Voltage Source Inverters In Variable Speed Drives with Induction Machines A Survey.
Jean-Sébastien Mariéthoz "" present to the faculty of engineering sciences and techniques institut des sciences de l'énergie section de génie électrique et électronique"" THESIS N°3188 2005.
K. YAKOUB, "Reducing the effects of zero sequence voltage in multilevel induction motor inverter associations. Magister thesis, University of Batna.
Ouahiba. F, modeling and nonlinear control of the MSAP association three-level voltage inverter. Magister thesis, University of Batna.2006.
A .M. Massoud, S, J, Finney and B, W, Williams « control techniques for multilevel voltage source inverters ».IEEE 2003.
F. Labrique, G. Séguier and R. Bausiere, "Les convertisseurs de l "électronique de puissance, T.4 La conversion continu - alternatif", Édition Lavoisier, France, 1995.